Sign in →

Test ID DWPAN Comprehensive Distal Weakness Gene Panel, Varies


Ordering Guidance


Targeted testing for familial variants (also called site-specific or known mutations testing) is available for the genes on this panel. See FMTT / Familial Variant, Targeted Testing, Varies. To obtain more information about this testing option, call 800-533-1710.

 

Customization of this panel and single gene analysis for any gene present on this panel are available. For more information see CGPH / Custom Gene Panel, Hereditary, Next-Generation Sequencing, Varies.



Shipping Instructions


Specimen preferred to arrive within 96 hours of collection.



Specimen Required


Patient Preparation: A previous bone marrow transplant from an allogenic donor will interfere with testing. Call 800-533-1710 for instructions for testing patients who have received a bone marrow transplant.

Specimen Type: Whole blood

Container/Tube: Lavender top (EDTA) or yellow top (ACD)

Acceptable: Any anticoagulant

Specimen Volume: 3 mL

Collection Instructions:

1. Invert several times to mix blood.

2. Send whole blood specimen in original tube. Do not aliquot.

Specimen Stability Information: Ambient (preferred)/Refrigerated

Additional Information: To ensure minimum volume and concentration of DNA is met, the preferred volume of blood must be submitted. Testing may be canceled if DNA requirements are inadequate.


Forms

1. New York Clients-Informed consent is required. Document on the request form or electronic order that a copy is on file.

The following documents are available:

-Informed Consent for Genetic Testing (T576)

-Informed Consent for Genetic Testing (Spanish) (T826)

2. Molecular Genetics: Neurology Patient Information

3. If not ordering electronically, complete, print, and send a Neurology Specialty Testing Client Test Request (T732) with the specimen.

Useful For

Establishing a molecular diagnosis for patients with distal weakness

 

Identifying variants within genes known to be associated with distal weakness, allowing for predictive testing of at-risk family members

Method Name

Sequence Capture and Next-Generation Sequencing (NGS), Polymerase Chain Reaction (PCR), Sanger Sequencing, and Dosage Analysis by Droplet Digital Polymerase Chain Reaction (ddPCR)

Reporting Name

Distal Weakness Gene Panel

Specimen Type

Varies

Specimen Minimum Volume

1 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Varies Varies

Reference Values

An interpretive report will be provided.

Day(s) Performed

Varies

Report Available

28 to 42 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

81443

LOINC Code Information

Test ID Test Order Name Order LOINC Value
DWPAN Distal Weakness Gene Panel 103731-6

 

Result ID Test Result Name Result LOINC Value
617546 Test Description 62364-5
617547 Specimen 31208-2
617548 Source 31208-2
617549 Result Summary 50397-9
617550 Result 82939-0
617551 Interpretation 69047-9
618178 Additional Results 82939-0
617552 Resources 99622-3
617553 Additional Information 48767-8
617554 Method 85069-3
617555 Genes Analyzed 48018-6
617556 Disclaimer 62364-5
617557 Released By 18771-6

Testing Algorithm

For more information see Hereditary Peripheral Neuropathy Diagnostic Algorithm