Sign in →

Test ID FPHIV Phenosense HIV Drug Resistance Replication Capacity

Method Name

CD4 cell culture assay for phenotypic recombinant virus
resistance

Reporting Name

Phenosense HIV

Specimen Type

Plasma EDTA


Specimen Required


Draw blood into two 5 mL PPT (pearl top) or EDTA (lavender top) tube(s). Immediately centrifuge (within 2 hours of collection) at 1000-1200 x g at room temperature for 10-15 minutes. Do not allow samples to remain in centrifuge after centrifugation. Remove plasma from cells immediately and transfer to a plastic screw cap tube.  Freeze immediately. Send 3 mL plasma in a screw-cap vial frozen.

 

RECOMMENDED:

  1. Patient's most recent viral load
  2. Viral load collection date

NOTE:  1. Intended for use only for patients with viral loads greater than or equal to 500 copies/mL. For best results, viral loads should be confirmed within two weeks prior to submission for testing at Monogram.

            2. Patient samples submitted <30 days apart are considered duplicate and will be canceled.


Specimen Minimum Volume

1 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Plasma EDTA Frozen

Reference Values

A final report will be attached in MayoAccess.

Day(s) Performed

Monday through Friday

Performing Laboratory

Monogram Biosciences, Inc

CPT Code Information

87903

87904 x12

LOINC Code Information

Test ID Test Order Name Order LOINC Value
FPHIV Phenosense HIV 49665-3

 

Result ID Test Result Name Result LOINC Value
Z1042 Phenosense HIV Unable to Verify

Report Available

14 to 21 days

NY State Approved

Yes