Sign in →

Test ID MMLYP Antimicrobial Susceptibility Panel, Yeast, Varies

Biohazard Infectious

Useful For

Determining in vitro quantitative antifungal susceptibility (minimum inhibitory concentration) of non-fastidious yeast

 

Testing may be warranted to aid in the management of certain circumstances, such as:

-Refractory oropharyngeal infections due to Candida species in patients who appear to be experiencing therapeutic failure with standard agents at standard doses

-Invasive infections due to Candida species when the utility of azole antifungal agents is uncertain (eg, when the infection is due to a non-Candida albicans organism)

Method Name

Minimum Inhibitory Concentration (MIC)

Antifungals included in the assay are: amphotericin B, anidulafungin, caspofungin fluconazole, 5-flucytosine, itraconazole, micafungin, posaconazole, and voriconazole.

Reporting Name

Susceptibility Panel, Yeast

Specimen Type

Varies


Shipping Instructions


1. See Infectious Specimen Shipping Guidelines in Special Instructions.

2. Place specimen in a large infectious container (T146) and label as an etiologic agent/infectious substance.



Necessary Information


Specimen source and suspected organism identification are required.



Specimen Required


Specimen Type: Organism in pure culture

Supplies: Infectious Container, Large (T146)

Container/Tube: Sabouraud's dextrose agar slant

Specimen Volume: Infecting yeast isolate

Collection Instructions: Organism must be in pure culture, actively growing. Do not submit mixed cultures.


Specimen Minimum Volume

NA

Specimen Stability Information

Specimen Type Temperature Time Special Container
Varies Ambient (preferred)
  Refrigerated 

Reference Values

Results reported in mcg/mL

Day(s) Performed

Monday through Saturday

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

87186

LOINC Code Information

Test ID Test Order Name Order LOINC Value
MMLYP Susceptibility Panel, Yeast 29577-4

 

Result ID Test Result Name Result LOINC Value
MMLYP Susceptibility Panel, Yeast 29577-4

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the U.S. Food and Drug Administration.

Forms

If not ordering electronically, complete, print, and send a Microbiology Test Request (T244) with the specimen.

Additional Tests

Test ID Reporting Name Available Separately Always Performed
SYP Susceptibility Yeast Panel No, (Bill Only) Yes

Testing Algorithm

When this test is ordered, Susceptibility Yeast Panel will be performed and charged. All yeast submitted will have susceptibility testing performed and billed as appropriate.

Report Available

3 to 7 days

NY State Approved

Yes